Qingdao AIP Intelligent Instrument Co., Ltd

Qingdao AIP Intelligent Instrument Co., Ltd Customer - Oriented, Striver - First

Manufacturer from China
Site Member
8 Years
Home / Products / Stator Vacuum Testing Machine /

Two Station Stator Testing Machine Under Vacuum State High Repeatability

Contact Now
Qingdao AIP Intelligent Instrument Co., Ltd
City:qingdao
Province/State:shandong
Country/Region:china
Contact Now

Two Station Stator Testing Machine Under Vacuum State High Repeatability

Ask Latest Price
Video Channel
Brand Name :AIP
Model Number :AIP89XX
Place of Origin :China
MOQ :1 set
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :50 sets per month
Delivery Time :45 work days
Packaging Details :Wooden case
station :Two station
OS :Window XP
Color :Green ( Customized)
Service :24 hours on-line
Remote control :Yes
Warranty :1 year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Stator Vacuum Surge Testing Machine, Test The Stator Under Vacuum State

1. Test specification

1.1 Test object: stator of motor

1.2 Test item: AC Hipot, insulation resistance, surge, DC winding resistance and direction of rotation

2.Technical specification

Test

Name

Stator Vacuum Surge Testing Machine

Hipot

Output voltage

range:(500 ~ 5000)V AC;

Breakdown current

range:(0.10~20.00)mA

precision:±(3.0%×reading value+3 words)

Duration time

range:(0.5~300)s,precision:±(0.1%×setting value+0.01s)

Insulation resistance

Output voltage

range:500/ 1000V DC,pace:≤1V/step

precision:±(3%×setting value+3V)

Resistance measuring

range:(1.0 ~ 99.9)MΩ,(100 ~500)MΩ

precision:±(3%×reading value+3 words),≤100MΩ

±(5%×reading value+5 words),>100MΩ

Duration time

range:(0.5~300)s,precision:±(0.1%×setting value+0.01s)

Surge

Impulse voltage

Range:(500~5000)V;

pace:≤1V/step

precision:±(3%×setting value+1V)

Waveform parameter

Area, area difference, range:(0~99)%

Resolution 0.1%,precision:±2.0%

Winding resistance

Resistance measuring

Range:15mΩ ~ 2kΩ,

Precision:±(0.5%×reading value+3 words)

temperature compensation

Temperature measuring

Range:(0~60.0)℃,precision:±0.1℃

Other function

Unbalance degree and resistance compensation function

Rotation

Magnetic field

CW/CCW/still

Data acquisition

Data analyze

Column diagram display the planned production, qualified, unqualified number etc.

Permission

Permission setting

Administrator: has the permission to change parameters

User: only has the permission to select model, start and stop the test.

User can be set with different operator’s name and separate password

The test data will record the test time and testing data of different operator

3. Testing machine introduction

3.1 The testing machine records the testing data and calculates the testing result automatically. Test can be performed continuously and steadily with automatic data analyzing and comparing function. The alarm will be triggered automatically if the stator is unqualified.

3.2 Over 1000 models of testing data can be saved in the testing machine, automatic model filter function. The established model and test item can be selected.

3.3 Test setting. Both the automatic test mode and standard test mode can be selected. Under standard test mode, click the start on the test interface by mouse to start the test. Under automatic test mode, pressing two start buttons to start the test. “If NG continue” or “If NG stop” are available options in case of failed test item during the test.

3.4 Light sensor protesting curtains are assembled on the two side of the testing machine to avoid the object enter into the testing area during the test. The alarm will be triggered if any object across the light sensor and the test will be stopped.

3.5 There are two test stations. Each station equipped with customized fixture inside of the vacuum cover.

4. Introduction of the stator surge test under vacuum status

4.1 How to detect the insulation resistance between the enameled wires?

Surge test can detect this.Although there are many ways to test the winding surge, the surge voltage impulse method is commonly used internationally. Because this method has the advantages of simple circuit and convenient operation, the voltage can be applied to the test object directly.

4.2 Why to use the vacuum testing machine to test the surge?

The windings imperfection is more easily to be detected under negative pressure environment. The arc will be longer at the same voltage if the pressure is lower. The testing environment is close to vacuum state but not complete vacuum given the fact that the discharge won’t occur under complete vacuum environment.

5. Stator vacuum surge testing machine reference picture

Two Station Stator Testing Machine Under Vacuum State High Repeatability

Inquiry Cart 0